SPECIFICATIONS | EV-200 | |
COOLING CAPACITY: A.T.P. U.N. Standard AT 30°C (Ambient) | ||
Cooling Capacity | 0°C | 2,200 |
-20°C | 1,250 | |
Evaporator blower performance | ||
Air Fow (@0°C Pa,m2/h) | 700 | |
Velocity (m/s) | 3.0 | |
Voltage Range (VDC) | ||
Input Voltage (V) | 210-450 | |
Compressor | ||
Compressor Type | Horizontal Hermetic | |
Power Consumption @0/30°C | ||
Total Power Consumption | 1480 | |
Weight (kg) | ||
Cond. | 75 | |
Evap. | 9 |
Note: Allowed lowest ambient temperature is -12°C.
SPECIFICATIONS | EV-300 | |
COOLING CAPACITY: A.T.P. U.N. Standard AT 30°C (Ambient) | ||
Cooling Capacity | 0°C | 3,000 |
-20°C | 1,700 | |
Evaporator blower performance | ||
Air Fow (@0°C Pa,m2/h) | 1,500 | |
Velocity (m/s) | 3.3 | |
Voltage Range (VDC) | ||
Input Voltage (V) | 260-450 | |
Compressor | ||
Compressor Type | Horizontal Hermetic | |
Power Consumption @0/30°C | ||
Total Power Consumption | 2230 | |
Weight (kg) | ||
Cond. | 84 | |
Evap. | 15 |
Note: Allowed lowest ambient temperature is -12°C.
SPECIFICATIONS | EV-500 | |
COOLING CAPACITY: A.T.P. U.N. Standard AT 30°C (Ambient) | ||
Cooling Capacity | 0°C | 4,300 |
-20°C | 2,400 | |
Evaporator blower performance | ||
Air Fow (@0°C Pa,m2/h) | 1,500 | |
Velocity (m/s) | 3.3 | |
Voltage Range (VDC) | ||
Input Voltage (V) | 250-750 | |
Compressor | ||
Compressor Type | Vertical Hermetic | |
Power Consumption @0/30°C | ||
Total Power Consumption | 3300 | |
Weight (kg) | ||
Cond. | 100 | |
Evap. | 23 |
Note: Allowed lowest ambient temperature is -12°C.
SPECIFICATIONS | EV-600 | |
COOLING CAPACITY: A.T.P. U.N. Standard AT 30°C (Ambient) | ||
Cooling Capacity | 0°C | 5,000 |
-20°C | 2,800 | |
Evaporator blower performance | ||
Air Fow (@0°C Pa,m2/h) | 2,500 | |
Velocity (m/s) | 3.0 | |
Voltage Range (VDC) | ||
Input Voltage (V) | 250-750 | |
Compressor | ||
Compressor Type | Vertical Hermetic | |
Power Consumption @0/30°C | ||
Total Power Consumption | 3600 | |
Weight (kg) | ||
Cond. | 100 | |
Evap. | 30 |